Analytic 100A, 12 V, 110 VAC, 60 Hz, 1 Bank, AC Battery Charger BCA-1505-110-12
BCA1505 AC Battery Charger
NSN#
BCA1505
BENEFITS
- Ultra-Quiet
- Power sensitive electronics without interference
- Rugged & Reliable
- Ensure years of safe and trouble free operation
- Fast & Accurate Charging
The BCA1505 battery charger provides up to 1350 watts to charge a 12 24, 36,
48 or 72 Volt battery system (2 bank) from a 110 or 220VAC source. The batteries
must share a common ground.
This all-new single board design incorporates state of the art switchmode
technology for unmatched efficiency and ultra-quiet operation. Multiple stages
of filtering reduce radiated or conducted noise to very low levels. Extra
features include visual indicators for low input voltage, charging and
over-temperature.
Safety features include both charger and battery over-temperature shutdown,
current limiting, short circuit protection with automatic recovery, input
undervoltage shutdown and output over-voltage crowbar.
Optional features include a 3-Bank Load Splitter. We are confident that you
will get many years of reliable service from this AC Battery Charger.
Features
- Military-Grade extrusion ensures a high tolerance for shock and vibration
- Ultra-quiet low EMI operation
- Can be left permanently connected
- Can function as a power supply
- Dry contact output fail relay
- User selectable 2 or 3 stage charging profile
- Temperature compensated charging
- Over-temperature shutdown
- 3 Bank Load Splitter Available
- Audible & visual indicators for output overload, low input voltage, low
output voltage & over-temperature
- Short circuit protection
- Output over-voltage crowbar
- Inrush Current Limiting with solid state bypass
- 110/220 Vac auto-ranging input option
- Thermostatically controlled fan
- 3 year parts and labour warranty
Applications
- Commercial Marine
- Military and DHS
- Electric Utilities and Substations
- Ideal as a Trade Show Power Supply for Auto Shows
- OEM Applications
- Field Work / Construction Sites
- Solar Power Systems
- Emergency Power Backup (UPS)
- Security Systems
- Charge any 12, 24, 32, 48 or 72 Volt (as well as custom voltage from
12-72VDC) Battery System
Electrical [Input]
Nominal Vac (ip) |
110 |
220 |
Actual (Vac) |
105-125 |
210-250 |
Input Amps (Max) |
16.2 |
8.1 |
Input Breaker |
25A |
Input Frequency |
45-65 Hz |
Noise on Input |
< 50mV |
Electrical [Output]
Output Nominal (op) |
12 |
24 |
32 |
48 |
72 |
Output Volts (DC) |
13.6 |
27.2 |
36.3 |
54.4 |
81.6 |
Absorption Voltage (VDC) |
13.6 |
28.8 |
38.4 |
57.6 |
86.4 |
Charging Amps |
75 |
50 |
37 |
25 |
16 |
Absorption to Float |
15A |
7.5A |
5.6A |
3.8A |
2.4A |
Battery Banks |
2(3 Bank Load Splitter Available) |
Battery Size
(Amp Hrs.) |
400-600 |
200-300 |
150-230 |
100-150 |
70-100 |
Output Crowbar |
17.0 ± 0.5V |
34.0 ± 1.0V |
45.4 ± 1.3V |
68 ± 2.0V |
102 ± 3.0V |
Equalize Voltage (VDC) |
15.5 |
31 |
41.3 |
62 |
93 |
Temperature Compensation Coefficient |
-15mV/°C |
-30mV/°C |
-40mV/°C |
-60mV/°C |
-90mV/°C |
Output Ripple & Noise |
< 50 mV |
Duty Cycle |
Continuous 100% for 24 hours per day |
Efficiency |
> 80% @ Maximum Output |
Stages |
2 or 3 selectable |
Regulation |
< +/- 0.5% |
Environmental Specification
Operating Temp. Range |
-25° to +40°C @ maximum output
Derate Linearly 2.5% per °C from 40°C
(Optional -40°C to +55°C extra wide temp. operation avail.) |
Humidity |
0 - 95% Relative Humidity
(non-condensing) with optional conformal coating |
Audible Noise |
NONE Ødb @ 3 ft (34.5 dB when fan operating |
Typical Service Life |
>10 years (87,600 hours) |
Isolation |
Input-Case & input-output 1500VDC
Output - Case 500VDC |
Vibration |
Meets Loose Cargo Test |
Mechanical Specification
Length |
16.16 in/ 41.14 cm |
Width |
8.35 in/ 21.21 cm |
Height |
4 in/ 10 cm
(withour carrying handle) |
Clearance |
1 inch (2.5 cm) all around |
Material |
Marine Grade Aluminium |
Finish |
Black |
Fastenings |
All 18-8 Stainless Steel |
Weight |
14.4 lb / 6.6 kg |
Connections |
Flying Leads |
Warranty |
3 years |
Safety |
Designed to meet CSA 22.2.107.1 & UL458 |

|