Analytic 22A, 24V Out, 280-360V In, Isolated DC/DC Battery Charger, 2 Bank, BCD610-300-24
BCD610 DC Battery Charger
NSN#
BCD610
BENEFITS
- Ultra-Quiet
- Power sensitive electronics without interference
- Rugged & Reliable
- Ensure years of safe and trouble free operation
- Fast & Accurate Charging
Downloads
Download BCD610 Series Datasheet
Download BCD610 Series Manual
The model BCD610 DC Battery Charger charges either 12V, 24V or 48V batteries
from a 110, 220 or 300VDC power source. Other battery voltages up to 360 volts
are also available by special order.
The all-new Current Mode switching design offers increased power and
reliability in a compact package. Extra input and output filtering reduce EMI to
extremely low levels. Reliability features include an input fuse, thermal
shutdown, current limiting, reverse battery hookup protection, output short
circuit shutdown with automatic recovery, and equalize charging cycle. The
output voltage is easily adjusted 1.0 volts above or below the standard output
voltage to accommodate special charging requirements.
Optional features include a Digital Volt/Ammeter, 3-Bank Charging, a Remote
Control Panel, and/or a second Battery Temperature Sensor. We are confident that
you will get many years of reliable service from this DC Battery Charger.
Features
- Fully Isolated Design
- Adjustable output voltage for charging standard or deep cycle lead-acid,
VRLA or Gel cell type battery
- Transient Voltage Suppressor
- Extremely rugged and well suited for marine and other demanding
environments
- High tolerance for shock and vibration
- Ultra-quiet low EMI operation
- Can be left permanently connected
- Spark free connection
- User selectable 2 or 3 stage charging profile
- Audible & visual indicators for output overload, low input voltage, low
output voltage & over-temperature
- Over-temperature shutdown
- Short circuit protection
- Output over-voltage crowbar
- Inrush Current Limiting with solid state bypass
- Dry contact output fail relay
- 3 year parts and labour warranty
Applications
- Marine & other Rugged Environments
- Electric Utilities and Substations
- Manufacturing Plants
- Steel Mills
- Military Applications (COTS)
- Industrial Controls
- OEM Applications
- Solar / Alternative Power Systems
- Fuel Cells
- Charge any DC/DC System
Electrical [Input]
Nominal Vac (ip) |
110 |
250 |
300 |
Actual (Vac) |
100-140 |
230-280 |
280-360 |
Input Amps (Max) |
8.2 |
3.6 |
2.9 |
Input Fuse (ATC) |
10 |
4 |
3 |
Noise on Input |
< 50mV |
Electrical [Output]
Output Nominal (op) |
12 |
24 |
48 |
Output Volts (DC) |
13.6 ? 0.05 |
27.2 ? 0.05 |
54.4 ? 0.05 |
Absorption Voltage (Vdc) |
14.4 |
28.8 |
57.6 |
Charging Amps |
40 |
22 |
11 |
Absorption to Float |
6.0Amps |
3.3Amps |
1.65Amps |
Output Adjustment(Vdc) |
? 1.0V |
Output Fuses(ATC) |
40Amp x2 |
30Amp x2 |
15Amp x2 |
Battery Banks |
1 or 2 (3 Bank Option Available) |
Battery Size
(Amp Hrs.) |
160-240 |
88-132 |
44-66 |
Output Crowbar |
16.0 ? 0.5V |
32.0 ? 1.0V |
63.9 ? 2.0V |
Output Ripple & Noise |
< 50 mV |
Regulation
(Line & Load) |
< +/- 0.5% |
Temperature Comp. |
-30 mV/?C |
-60 mV/?C |
-120 mV/?C |
Duty Cycle |
Continuous 100% for 24 hours per day |
Efficiency |
> 75% @ Maximum Output |
Stages |
2 or 3 (user selectable) |
Environmental Specification
Operating Temp. Range |
-25? to +40?C @ maximum output
Derate Linearly 2.5% per?C from 40?C
(Optional -40?C extra wide temp. operation avail.) |
Humidity |
0 - 95% Relative Humidity
(non-condensing) with optional conformal coating |
Audible Noise |
NONE - ?db @ 3 ft |
Typical Service Life |
>10 years (87,600 hours) |
Isolation |
Input-Case & input-output 1500VDC
Output - Case 500VDC(1500VDC @ 48V Output) |
Mechanical Specification
Length |
14.5 in / 36.8 cm |
Width |
9.9 in / 25.1 cm |
Height |
3.0 in / 7.6 cm |
Clearance |
1 inch (2.5 cm) all around |
Material |
Marine Grade Aluminium |
Finish |
Black Anodize / Powder Epoxy Coat |
Fastenings |
All 18-8 Stainless Steel |
Weight |
7.6 lb / 3.3 kg |
Connections |
Four contact output terminals |
Warranty |
3 years |
Safety |