Analytic Heavy Duty 40-60V In, 12V Out, 20A, Isolated DC/DC Converter VTC315-48-12
The model VTC315 Voltage Converter supplies either 12V, 24V, or 48 VDC from a
24V or 48VDC power source.
All new Current Mode switching design offers increased power and reliability
in a compact package. Extra input and output filtering reduce EMI to extremely
low levels. Reliability features include an input fuse, thermal shutdown,
current limiting, reverse battery hookup protection and output short circuit
shutdown with automatic recovery.
The output voltage is easily adjusted 1.0 volts above or below the standard
output voltage. Devices connected to the converter are protected by an output
overvoltage crowbar circuit.
Available options include a Remote Control and/or a Digital Volt Ammeter to
monitor output current and voltage.
Benefits
- Ultra-Quiet
- Power sensitive electronics without interference
- Rugged & Reliable
- Ensure years of safe and trouble free operation
- Download Data Sheet
Features
- Fully Isolated Design
- Adjustable output voltage
- Audible & visual indicators for constant current, low input voltage, low
output voltage & over-temperature
- Over-temperature shutdown
- Short circuit protection
- Output overvoltage crowbar
- Cycle by cycle current limiting
- Reverse input protection
- Transient Voltage Suppression
- Ultra-quiet low EMI operation
- Dry contact output fail relay
- Custom input / output voltages from 8 to 55 VDC
- Remote control option
- Digital Volt/Ammeter option
- Wide-Temperature operation Available
- Conformal Coating and/or Harsh Environment Ruggedization Available
Applications
- Marine & other rugged environments
- Mobile Offices (TV and Radio Vans)
- Automotive / RV
- Electric Utilities and Substations
- Base Station Power(Radio & Telecommunications)
- Industrial Controls(OEM Applications)
- Field Work / Construction Sites
- Solar Power Systems
- Emergency Power Backup (UPS)
- Security Systems
- Product Burn-in Facilities
Electrical [Input]
Nominal Vac (ip) |
24 |
48 |
72 |
Actual (Vdc) |
20-35 |
40-60 |
65-90 |
Input Amps (Max) |
22 |
9.6 |
6.5 |
Input Fuse |
MDA25 |
MDA15 |
MDA10 |
Noise on Input |
< 25mV |
Electrical [Output]
Output Nominal (op) |
12 |
24 |
48 |
Output Volts (DC) |
13.6 ? 0.05 |
27.2 ? 0.05 |
54.4 ? 0.05 |
Output Amps |
20cont./22.5peak |
10cont./12.5peak |
5.0cont./6.0peak |
Output Adjustment |
? 1.0 |
Output Crowbar |
16.0 ? 0.5V |
32.0 ? 1.0V |
63.9 ? 2.0V |
Switching Frequency |
60 ? 2 KHz |
Idle Power |
< 10 Watts |
Output Ripple & Noise |
< 25 mV |
Transient Response |
< 2V for 50% Surge |
Regulation
(Line & Load) |
< +/- 0.5% |
Duty Cycle |
Peak 20% for 10 min max
Continuous 100% for 24 hours per day |
Efficiency |
> 80% @ Maximum Output |
Environmental Specification
Operating Temp. Range |
-25? to +40?C @ maximum output
Derate Linearly 2.5% per ?C from 40?C
(Optional -40?C extra wide temp. operation avail.) |
Humidity |
0 - 95?C Relative Humidity
(non-condensing) with optional conformal coating |
Audible Noise |
NONE - 0db @ 3 ft |
Typical Service Life |
>10 years (87,600 hours) |
Isolation |
Input-Case & Input-Output 1500VDC (500V @ 24V I/P)
Output-Case 500VDC (1500VDC @ 48V O/P) |
Mechanical Specification
Length |
9.6 in/ 24.4 cm |
Width |
8.2 in/ 20.8 cm |
Height |
3.5 in/ 6.4 cm |
Clearance |
1 inch (2.5 cm) all around |
Material |
Marine Grade Aluminium |
Finish |
Black Anodize / Powder Epoxy Coat |
Fastenings |
All 18-8 Stainless Steel |
Weight |
7.5 lb / 3.4 kg |
Connections |
Four contact output terminals |
Warranty |
3 years |
Safety |
Approval to cETLus Standards pending |
|