General specifications |
Output voltage | 115/120 V — 50/60 Hz (selectable) |
Output waveform | true sine |
Nominal battery voltage | 12v |
Recommended battery capacity | = 200 Ah |
Continuous power at 25 °C / 77 °F, cos phi 1 | 2000 W |
Continuous power at 40 °C / 104 °F, cos phi 1 | 2000 W |
Peak load (1 min.) | < 2300 W |
Peak load (1 s) | < 3500 W |
AC connection | North American socket with GFCI |
Galvanic isolation | Yes |
Efficiency | 92 % |
Display/read-out | LED indication: battery voltage, load level, status |
Alarms | potential free alarm contact |
Dimensions, hxwxd | 9.8 x 17.4 x 3.3 inch |
Weight | 11.5 lb |
Technical specifications |
Technology | high frequency, input & output fully isolated |
Low battery voltage, switches off at | 10,5 V |
Low battery voltage, switches on at | 12,5 V |
High battery voltage, switches off at | 16,5 V |
High battery voltage, switches on at | 14,5 V |
Input current (nominal load) | 200 A |
No-load power consumption (ON mode) | < 1.8 A |
No-load power consumption (energy saving mode) | < 0.1 A |
Minimal DC fuse (slow blow) | 250 A |
Minimal cable size | 70 mm2 |
Harmonic distortion typical | < 3 % |
Cos phi | all power factors allowed |
Temperature range (ambient temp.) | -4 °F to 140 °F |
Cooling | temperature and load controlled fan |
Protection degree | IP21, horizontal wall mounting |
Protections | over-temperature, overload, short circuit, high/low voltage, reverse polarity (fuse) |
MasterBus compatible | yes, using a MasterBus AC Master Interface |