Specifications sine wave inverter |
|
Nominal DC voltage |
12 V (10.2–16 V) |
|
Output voltage |
120 V |
|
Output frequency |
60/50 Hz (configurable) |
|
Output waveform |
true sine |
|
Continuous power at 40 °C / 104 °F, cos phi 1 |
1500 W |
|
Peak power (30 sec) |
2250 W |
|
Surge power (5 sec) |
3000 W |
|
Max. efficiency |
93 % |
|
Battery no-load power consumption |
30 W (on mode) / < 1 mA (off mode) |
|
Energy saving mode consumption |
10 W |
|
Synchronise with mains |
yes |
| |
|
Specifications battery charger |
|
Input voltage range |
90–140 V |
|
Max. input current |
9 A (adjustable) |
|
Max. charge current at 40 °C / 104 °F |
60 A at 14.25 V (configurable) |
|
Battery temperature sensor |
yes, included |
|
Battery voltage sense |
automatic compensation |
| |
|
Specifications transfer system |
|
AC input |
30 A (switched) |
|
AC output |
40 A |
|
AC input fuse |
yes |
|
Transfer speed |
10 ms |
|
Transfer voltage range |
wide: 70–140 V / narrow: 90–140V |
|
Transfer frequency range |
40-65 Hz |
| |
|
General specifications |
|
Galvanic isolation |
yes |
|
Display/read-out |
LED display |
|
Dimensions, hxwxd |
371 x 284 x 155 mm
14.6 x 11.2 x 6.1 inch |
|
Weight |
6.9 kg
15.2 lb |
|
Compliance |
ABYC A31, UL1236, UL1741, SAEJ1171, FCC class B |
| |
|
Technical specifications |
|
Charge characteristic |
UoUo, automatic / 3-step+ for flooded, Gel/AGM and MLI, configurable |
|
Recommended battery capacity |
120-600 Ah (based on gel batteries, may differ for other types) |
|
Ground relay |
yes, configurable by means of mechanical jumper |
|
Temperature range (ambient temp.) |
-25 °C to 60 °C, derating > 40 °C
-13 °F to 140 °F |
|
Cooling |
vario fan |
|
Protection degree |
IP23 (vertical mounting) |
|
Safety class |
IEC protection class I |
|
Humidity protection |
conformal coating, max. 95 % relative humidity, non condensing |
|
Protections |
over-temperature, overload, short circuit, high/low battery voltage |
|
Power Assist |
yes, supports AC input with power from the battery |
|
Power Sharing |
yes, allows you to select AC Input fuse setting |
|
MasterBus compatible |
yes |
|
CZone / NMEA 2000 compatible |
yes |