Inverter
24/1600 120v VE.Direct Nema GFCI (UL 458)
The
VE.Direct port can be connected to:
·
A computer (VE.Direct to USB interface cable needed)
·
Apple and Android smartphones, tablets, MacBook’s and other
devices (VE.Direct Bluetooth Smart dongle needed)
Fully
configurable:
·
Low battery voltage alarm trip and reset levels
·
Low battery voltage cut -off and restart levels
·
Dynamic cut -off: load-dependent cut-off level
·
Output voltage 2 10 - 245V
·
Frequency 50 Hz or 60 Hz
·
ECO mode on/off and ECO mode sense level
Monitoring:
In- and output voltage, % load and alarms
Proven
Reliability
The full bridge plus toroidal transformer topology has proven its reliability
over many years. The inverters are short circuit proof and protected against o
verheating, whether due to over load or high ambient temperature.
High
start-up power
Needed to start loads such as power co nverters for LED lamps, halogen lamps or
electric tools.
ECO mode
When in ECO mode , the inverter will switch to stan dby when the load decreases
below a preset value (min load: 15W). Once in standby the inverter will switch
on for a short period (adjustable, default: every 2,5 seconds) . If the load
exceeds a preset level, the inverter will remain on.
Remote
on/off
A
remote on/off switch can be connected to a two-pole connecto r, or between
battery plus and the left-hand contact of the two-pole connector.
To
transfer the load to another AC source: the automatic transfer switch
For our low power inverters , we recommend our Filax Automatic Transfer Switch.
The Filax features a very short switchover time (less than 20 milliseconds) so
that computers and other electronic equipment will continue to operate without
disruption.
DC
connection with screw terminals
No special tools needed for installation
Output
Sockets
GFCI